COA Instruments

IRT-Based COA Submissions: Keep Item, Model, and Score Documentation Linked

Trace IRT-based COA scores in ADQS back to ZQ item parameters, QS responses, CAT order, and scoring builds under FDA CDER's November 2023 v1.0 specification.

· · 10 min read

Editorial still life of an unlabelled questionnaire sheet, a narrow calibration ledger and an analysis printout with one highlighted row running across all three, a charcoal pencil laid along it on warm parchment

To keep an item response theory (IRT) clinical outcome assessment (COA) submission auditable, build an item-level manifest that identifies the exact instrument or item-bank version and links item definitions and calibration parameters in the U.S. Food and Drug Administration (FDA) example ZQ dataset to participant-level Study Data Tabulation Model (SDTM) responses in QS (or the applicable Questionnaires, Ratings, and Scales domain), the scoring method and software build, and the corresponding item, score, and precision records in Analysis Data Model (ADaM) ADQS. Every link in that manifest should point directly to the submitted program code, Define-XML, and reviewer guides.

When the trial uses computerized adaptive testing (CAT)—an adaptive administration method that selects subsequent items based on a participant's prior responses—FDA recommends that the package also document the item-selection or routing algorithm, the starting and stopping criteria with their justification, the item administration order (QSREFID), and the scored and responded-item counts in ADQS so a reviewer can confirm the stopping rule was met. Equally important, the tabulation and analysis files should keep administered nonresponses, items never selected by the adaptive algorithm, and an entire planned but unadministered CAT assessment distinct from one another. These recommendations follow FDA Center for Drug Evaluation and Research (CDER) November 2023 v1.0 final Level 2 technical specifications, and sponsors should discuss scope and timing with the review division early in the investigational new drug (IND) phase.

Which COAs the FDA specification covers

FDA's official guidance index lists Submitting Clinical Trial Datasets and Documentation for Clinical Outcome Assessments Using Item Response Theory (docket FDA-2018-D-1216) as Final Level 2 guidance issued by CDER. Version 1.0 of the FDA IRT COA technical specification (November 2023, §§1.1–1.3) establishes a nonbinding framework for marketing applications to CDER that rely on COAs built or scored with item response theory. Because its dataset tables and appendices are illustrative and non-exhaustive, sponsors can propose alternative representations when justified and discussed with the review division.

The specification applies to two operational cases (§1.2):

  • Fixed forms developed and/or scored using IRT: Static questionnaires or short forms either constructed from an IRT-calibrated item bank or scored using IRT parameter estimates (including fixed forms where an IRT model informed item selection during development even if a summed or raw score is submitted).

  • IRT-based computerized adaptive testing (CAT): Dynamic assessments in which a routing engine selects each next item from a calibrated bank based on the participant's previous responses until a stopping rule is satisfied.

Define the acronym consistently across the protocol, data management plan, and reviewer guides: in clinical trial operations, IRT also denotes interactive response technology used for randomization, drug supply, and unblinding—such as in the European Medicines Agency's Guideline on computerised systems and electronic data in clinical trials (Annex 5 §A5.2)—which is entirely separate from psychometric item response theory.

Agree on what to submit during the IND phase

The documentation chain can span several owners—psychometricians, electronic COA (eCOA) vendors, instrument owners and statistical programmers—so FDA's timing recommendation matters as much as its content list. In §§3.1–3.2 of the FDA IRT specification, CDER strongly recommends consulting the Agency early in the IND phase to determine the appropriate level of evidence and to agree on the proposed fixed form and/or item bank before the registration trial(s) are conducted. It recommends submitting the agreed COA evidence, including the item dataset, during the IND phase; if that is not possible, the sponsor should consult the review division.

Separate what every IRT-covered COA requires from the conditional artifacts triggered only by IRT scoring or adaptive administration. When a fixed form falls under the specification solely because it was developed with IRT rather than scored with IRT parameters, mark IRT-scoring artifacts as not applicable with an explicit rationale and document how the submitted score is actually derived.

Documentation LayerTrigger ConditionRecommended Documentation (FDA IRT §3.1)Typical Owner & Handoff Risk
Core instrument and bank packageAll covered fixed forms and CAT instrumentsCOA name, version and copyright information (if applicable); a copy of the fixed form with all items and response options, or a screenshot of every CAT bank item; the item dataset (ZQ); reporter instructions; user manual with training, administration and scoring instructions; operational details; server, power and internet outage handling; supporting software datasets and code; a detailed description of the calibration sampleCOA / eCOA lead & psychometrician; risk of missing bank-wide screenshots or outdated form version labels
IRT scoring additionsTriggered when scores are estimated via IRTScoring details, including the methods for generating scores (e.g., theta score, scaled score); conversion table(s) from theta to transformed scores such as T-scores, if applicable; psychometric software name and versionStatistical programming / vendor scoring owner; risk of silent scoring-build updates between IND and NDA/BLA
Adaptive administration additionsTriggered when administered via CATDetails of the item-selection or routing algorithm, including content constraints and/or item exposure control if applicable; starting criteria with justification; termination criteria (stopping rule) with justificationeCOA vendor & psychometric lead; risk of undocumented stopping-rule overrides or outage fallback discrepancies

Build the item-to-score submission manifest

A submission checklist that merely confirms files exist does not prove that a participant's score in ADQS came from the calibration parameters in ZQ and the responses in QS. The item-to-score manifest below is an editorial implementation aid—not an FDA form or regulatory requirement—designed to bind version identifiers, dataset locators, source clauses, owners, and reconciliation outcomes into a single reviewable map. Workflow status labels such as Verified, Missing, Not Applicable, and Unresolved function strictly as internal editorial review controls.

flowchart LR
  ZQ["ZQ Item and Calibration Dataset: ZQCAT, RDOMAIN, ZQTESTCD, ZQSE"]
  QS["SDTM Participant Responses: QS, FT, or RS with QSTESTCD and QSREFID"]
  SCORE["Scoring and CAT Engine: Software Version, Conversion, Start and Stop Rules"]
  ADQS["ADQS Analysis and Reviewer Docs: PARAMCD, AVAL, Score SE, Define-XML, ADRG, cSDRG"]
  ZQ -->|"Item universe and parameter version"| SCORE
  QS -->|"Item code, response, and CAT order"| SCORE
  QS -->|"QSSEQ source linkage and status"| ADQS
  SCORE -->|"Derived raw, theta, and scaled outputs"| ADQS
  ADQS -.->|"Backward audit of version and rule match"| ZQ
Bidirectional traceability chain connecting nonsubject item calibration (ZQ), participant responses (QS/QRS), scoring implementation, and analysis outputs (ADQS).

Three rules from the FDA IRT specification anchor this manifest. First, the nonsubject ZQ dataset (§4.1.1, Table 1, Appendix 5.1) should include every item in the bank whenever a bank was used in development or administration, or all fixed-form items when no bank was used, along with permitted responses, model-dependent parameter values, and standard errors (ZQSE) for estimated numeric parameters. Second, in the SDTM respondent example (§4.1.2, Table 2), QSTESTCD corresponds to ZQTESTCD and QSREFID records CAT administration order even when an administered item receives no response; note that FDA uses QS as shorthand and FT (Functional Tests) or RS (Disease Response and Clin Classification) may apply under the governing CDISC QRS supplement. Third, verify applicable CDISC SDTM, ADaM, and controlled terminology versions against FDA's Data Standards Catalog using study-start rules (FDA Study Data for Submission to CDER and CBER; Study Data Technical Conformance Guide (sdTCG) v6.3, October 2026, sections on reviewer's guides, data definition files (§4.1.4.5) and study data traceability).

Assessment & VersionItem / Output IdentifierApplicabilityDataset / Document & Record LocatorSource ClauseEvidence OwnerReconciliation Outcome (Editorial Status)
Instrument and inputs: COA/form version, bank version (if CAT or bank-derived), response codingSource item ID, QSTESTCD (mapped to ZQTESTCD), assessment timepoint, CAT order (QSREFID)Applies to all covered fixed forms and CAT (apply QS, FT, or RS per QRS supplement)Static form or CAT bank screenshots, instructions, administration manual; SDTM QS located by STUDYID, USUBJID, visit/timepoint, QSTESTCD, and QSREFIDFDA IRT §§3.1–3.2, §4.1.2, Table 2; CDISC QRSCOA lead & clinical data standards leadVerified when every administered QSTESTCD and CAT order resolves to current form/bank screenshots; otherwise Missing or Unresolved
Item and calibration: item bank or fixed-form universe and parameter-set versionZQCAT, RDOMAIN, ZQTESTCD, model parameter codes, ZQSEFull bank if used in development or administration; all fixed-form items if no bank was usedNonsubject ZQ dataset (permitted values/bounds, model parameters, units/scale, ZQSE) + calibration sample & model specification documentFDA IRT §4.1.1, Table 1, Appendix 5.1Psychometrician & data standards leadVerified when ZQ parameter-set version matches the scorer's exact parameter set and calibration report; otherwise Missing or Unresolved
Scoring and adaptive administration: scoring build, software version, CAT routing versionScoring method, software name/version, conversion rule; CAT start/stop/routing IDsIRT scoring artifacts conditional on IRT scoring; CAT rules conditional on CAT; mark Not Applicable with rationale if fixed form is only IRT-developedVersioned scoring program/implementation, conversion spec, CAT algorithm & start/stop rationale linked to QSREFID and scored/responded-item countsFDA IRT §§3.1–3.2, §4.2.1Statistical programmer & eCOA scoring vendorVerified when run metadata confirms exact parameter-set and software versions, or Not Applicable with documented non-IRT derivation
Analysis and documentation: ADQS endpoint build and submission metadata packageADQS measure/version, PARAMCD, AVAL/AVALC, raw/theta/scaled outputs, participant score SEs, QSSEQRecommended for the marketing application; Trial Summary (TS) FDATCHSP marker is optionalADQS (with CAT scored/responded counts & missingness reasons), Define-XML, ADRG, cSDRG, submitted ADaM/analysis programs, SAP missing-data pointerFDA IRT §§1.3, 4, 4.1.3, 4.2.1–4.2.2, Table 4, Appendix 5.3; sdTCG v6.3 reviewer's guides, §4.1.4.5 and Study Data TraceabilityBiostatistician, ADaM programmer & regulatory leadVerified when every ADQS derivation reproduces from submitted code, Define-XML, and QS; keep optional TS flag separate from core lineage

Record which items were administered

FDA's specification asks for the scored count and the responded (total item) count in ADQS so a reviewer can confirm that the CAT termination criteria were met and that the theta score was not calculated prematurely, and it stresses understanding the reasons for and prevalence of missing COA data (§§4.1.2.2 and 4.2.1–4.2.2). Collapsing an unselected CAT bank item into the same status as an administered item that a participant skipped undermines both the stopping-rule check and estimand-aligned missing-data review.

The FDA IRT specification (Table 3, §4.1.2.3, §§4.2.1–4.2.2, Appendices 5.2–5.3) and sdTCG v6.3 §4.1.1.3 support distinct data-representation rules for the six states below. Data representation is separate from statistical handling: FDA specifies no imputation method in the IRT technical document, and if missing values are imputed or represented by phantom records in ADQS, document the rule: FDA places imputation rules in the statistical analysis plan (SAP) and documentation for derived parameters in Define-XML and the ADRG. Never assign a reason for missingness when none was collected; leave uncollected causes unknown.

Assessment StateSDTM (QS Example) RuleADaM (ADQS) & Documentation RuleCommon Error to Avoid
Administered item with nonresponseKeep item row; set QSSTAT to NOT DONE and record reason if known; populate QSREFID for CAT orderCopy SDTM missing record and known reason as appropriate; reflect in CAT responded vs. scored countsDropping QSREFID on skipped CAT items or fabricating an uncollected reason
Missed fixed-form assessmentInclude planned item rows and applicable source-score rows with QSSTAT = NOT DONE and reason if knownCopy missing item/assessment records and known reasons; apply SAP-prespecified missing-data handlingOmitting the entire visit from QS without tabulation trace
Unadministered planned CAT assessmentRepresent the missed visit with a single QSALL row (NOT DONE and reason if known)Copy the QSALL record for traceability; FDA's example then derives PHANTOM records (null AVAL) for each summary score and standard error, or apply SAP-prespecified imputation; document in Define-XML and ADRGExpanding a missed CAT visit into dummy rows for every item in the bank
Unselected CAT bank itemOmit from QS (item remains defined in ZQ)Do not copy as missing data and do not generate phantom rows for ordinary unselected bank itemsTreating unselected adaptive items as missing data or NOT DONE
Conditionally branched item (developer skip logic)Follow sdTCG v6.3 §4.1.1.3: record/score per developer instructions and flag the branch; if unavailable, use status, branch flag, null result, and optional reasonAlign ADQS derivations and Define-XML with the documented branching ruleApplying ad hoc skip rules or failing to flag branched items in QS
Genuinely missing record absent from QSNo corresponding QS row existsDerive phantom records only when no QS row exists (one option FDA illustrates) or apply SAP-prespecified imputation; document the derivation in Define-XML and ADRGBlanket-generating phantom rows without SAP specification or conflating them with unselected CAT items

Similarly, keep instrument-specific missing-item rules bounded to the exact instrument and manual that authorize them. For example, our analysis of skipped PROMIS Physical Function items explains why fixed-form conversion tables break when items are omitted and when response-pattern scoring applies—a rule tied to that instrument's manual rather than a generic scoring rule for every IRT-based COA.

Check one score against the files a reviewer receives

Before assembling the final eCTD package, trace at least one participant's score in both directions—backward from ADQS and forward from ZQ—using only the exact datasets, programs, and guides that a regulatory reviewer will receive. The worked example below is synthetic and invented strictly for illustration; it does not represent an actual clinical study, licensed instrument, participant dataset, or vendor scoring engine.

In this synthetic CAT scenario for fictitious assessment S001 at Visit 2, tracing backward from a populated latent trait theta score in ADQS finds participant item DEMO01 in QS with a recorded response and CAT administration order QSREFID = 1. Looking up ZQTESTCD = DEMO01 in ZQ succeeds—the item code matches, and the package manifest declares Bank v2. However, inspecting the submitted scoring run metadata exposes that the scorer actually executed against Bank v1.

Synthetic Record (S001)Item / Row CodeZQ & Manifest StateQS Tabulation StateScorer Run & ADQS StateEditorial Status & Required Action
Visit 2 — Administered response (version check)DEMO01Present in ZQ; ZQ and manifest cite Bank v2QSTESTCD = DEMO01, response populated, QSREFID = 1ADQS theta populated, but scoring run log cites Bank v1Unresolved: Code match cannot clear version conflict; request versioned parameter set and run log from scoring owner and reconcile ADQS via documented process
Visit 2 — Contrast: Administered nonresponseDEMO02Present in ZQQSTESTCD = DEMO02, QSSTAT = NOT DONE, QSREFID = 2Copied to ADQS with QSSTAT and known reason; excluded from the responded (total item) countVerified (tabulation): Administration order and nonresponse state are preserved
Visit 2 — Contrast: Unselected CAT bank itemDEMO03Present in ZQ as part of full calibrated bankIntentionally omitted from QSNot represented as missing or phantom in ADQSVerified (omission rule): Distinct from administered nonresponse
Visit 3 — Contrast: Missed planned CAT assessmentQSALLBank remains defined in ZQSingle QSALL row with NOT DONE and reason if knownQSALL record copied for traceability; summary scores and standard errors carried as PHANTOM records (null AVAL) or per SAP-prespecified imputationVerified (missed visit): Does not expand into item-level rows

Notice why a simple automated check fails here: DEMO01 appears in both QS and ZQ, and ADQS contains a non-null theta value. Yet an item-code match and a populated output cannot resolve a mismatch between ZQ (Bank v2) and the scoring run (Bank v1). The package team must record that score lineage as Unresolved, request the actual versioned parameter set and run log from the scoring owner, reconcile the ADQS output through the documented scoring and change-control process, and align Define-XML, ADRG, cSDRG, and submitted programs before submission.

Boundary between submission traceability and fit-for-purpose evidence

Even a completely reconciled ZQ-to-QS-to-ADQS manifest establishes only data and scoring traceability—it does not prove that the COA is fit for purpose, that the IRT model fits the trial population, or that the resulting endpoint supports a regulatory claim. Under FDA's final October 2025 PFDD Guidance 3 (§§II.C and IV.E), context-of-use evidence, psychometric framework rationale, model assumptions, and model fit remain distinct evidentiary requirements, and FDA endorses no single psychometric approach (see fit-for-purpose COA evidence under PFDD Guidance 3). Meanwhile, endpoint construction and meaningful-change interpretation sit under Guidance 4—listed as draft on FDA's official Patient-Focused Drug Development Guidance Series index (see constructing COA endpoints under draft PFDD Guidance 4).

Scope and method boundaries also govern how teams apply this guide. The mapping reflects U.S. CDER submission specifications as of November 2026 rather than a universal global template, and its worked check is synthetic with no tested execution against a licensed instrument or vendor engine. Confirm study-start CDISC standard versions, controlled terminology packages, and QRS domain rules (QS, FT, or RS) against FDA's Data Standards Catalog and your IND-phase review division agreements before locking submission files.