Measurement & Operations

Who Counts in PRO Completion Rates for Oncology Trials?

Reconcile patient-reported outcome (PRO) counts in randomized oncology trials. Show score availability among those due and across the randomized arm.

· · 11 min read

Two rows of blank assessment cards with navy and burgundy bands, arranged in progressively thinner stacks.

Find the denominator behind the dashboard

At Cycle 4 in a synthetic randomized oncology trial, Arm B has a higher patient-reported outcome (PRO) completion rate among those due than Arm A (26/28, 92.9% versus 30/36, 83.3%). Arm B has fewer scores among everyone randomized (26/40, 65.0% versus 30/40, 75.0%).

Before the Cycle 4 window opened, nine participants in Arm B died and three withdrew consent for further PRO collection. Those 12 assessments came off the due roster, leaving 28. The randomized denominator stayed at 40. Putting both fractions on the same report shows how much of the arm contributed a score and how often the team obtained one when collection was due.

FDA’s November 2023 oncology submission specifications use the randomized arm for clinical-benefit availability and a visit-specific expected group for safety and tolerability completion. FDA recommends both displays when both objectives are specified. The 2025 SISAQOL-IMI consensus separately recommends showing completion and availability by arm and time point in randomized trials. FDA technical specifications, §4.2 · SISAQOL-IMI guidebook, Anal1_GEN

Start with four counts for each arm, visit and instrument. The difference between scheduled and due shows changes in who could be assessed under the collection rules. The next two differences show where a due assessment yielded no accepted response and where an accepted response yielded no target score. Use the target score for both operational rates in this example. For a submission or trial report, reconcile the operational counts against the populations and completion rule specified for that display.

Build four counts for each arm and visit

Give each assessment opportunity one ledger row keyed by coded participant, instrument and version, and planned occurrence. A transfer can bring in several records for one opportunity. Use the prespecified assignment and duplicate rules to count the accepted response once.

flowchart LR
  S["Scheduled opportunities"] --> D["Operationally due"]
  S -. "No eligible collection time in window" .-> X1["Not due"]
  D --> R["Qualifying records received"]
  D -. "No accepted response by cutoff" .-> X2["Due without a qualifying record"]
  R --> E["Evaluable target scores"]
  R -. "No target score under planned rule" .-> X3["Received without target score"]
  E --> Q1["Operational completion = Evaluable / Due"]
  E --> Q2["Fixed-arm availability = Evaluable / Randomized"]
How one scheduled assessment contributes to the four counts and two operational rates.

Defining scheduled, due, received, and evaluable

  1. Scheduled opportunities. Start from the nominal protocol schedule for that instrument and occurrence, including opportunities that later became ineligible. In the example each closed window has one scheduled opportunity per randomized participant. At a live cut, distinguish future and open windows from the closed windows being reconciled.

  2. Operationally due assessments. For this ledger, count a scheduled assessment as due if the protocol called for collection and the participant was alive and collection was permitted for any part of the visit window. Use the effective dates of disposition and consent changes. Confirm separately who qualifies for each reporting denominator and which values the estimand needs.

  3. Qualifying response-bearing records received. Count a due assessment when participant responses are reconciled to the occurrence under prespecified identity, timing and record selection rules by the reporting cutoff. Under the example’s rule, a timely, permitted response uploaded later can qualify when the transfer is reconciled by the cutoff. Track duplicates, out-of-window returns, unassigned records and pending transfers separately.

  4. Evaluable target scores. Count accepted records that yield the prespecified item, subscale or total score under the planned scoring rules. For example, an incomplete response may yield a score for one subscale if that subscale meets the manual’s missing-item rule. Keep a separate evaluability flag for each target score and retain the scoring version.

A public LEAP-001 supplemental statistical analysis plan (SAP) illustrates why rate labels need a formula. Its completion rate among treated participants (CR-T) and compliance rate among eligible participants (CR-E) both count treated participants with at least one answered item. The plan separately defines instrument completeness by whether at least one valid score can be calculated under the scoring manual. A return can therefore count toward the named rate without yielding the score the trial needs. LEAP-001 China Extension supplemental SAP, §3.6.3.1

FDA’s October 2024 final Core PRO guidance for trials of anticancer therapies intended to show effects on survival, tumor response or progression recommends planning missing-data mitigation and completion monitoring in the protocol, documenting missing reasons in the analysis dataset, prespecifying the analysis and explaining departures from the scoring manual. The 2023 submission specifications defer to the scoring manual to determine instrument completion and show unknown or uncollected reasons separately. FDA Core PRO guidance, §V.B · FDA submission specifications, §4.2 · COA licensing and scoring documentation

Ledger stageCount definitionAudit fields requiredDifference accounted to next stage
1. ScheduledRandomized participants with a nominal assessment opportunity at the visitCoded participant ID, masked arm code as authorized, visit, instrument and version, schedule version, and window boundsScheduled minus Due shows opportunities with no eligible collection time under the protocol and consent rules.
2. DueScheduled assessments with eligible collection time during the windowDue flag, effective date and time, disposition source reference, and scope of follow-up consentDue minus Received includes missed visits, one-visit refusals, capture failures, out-of-window-only returns, mid-window loss of eligibility without a qualifying response, and unknown reasons.
3. ReceivedQualifying response-bearing records accepted and reconciled to the visit by cutoffSource record ID, participant completion and transfer timestamps where available, assigned occurrence, and accepted-record flagReceived minus Evaluable counts accepted responses that yielded no target score under the planned rule.
4. EvaluableRecords yielding the prespecified item, subscale, or total scoreTarget score flag, scoring version, and documented reason and source for scoring failuresCounts toward both operational numerators. Check analysis eligibility separately.

Account for every change in who was due

Apply disposition events to the visit window using their effective dates. A death before the window or withdrawal of consent for PRO follow-up before the window can remove the opportunity from Due. If an event occurs during the window, record when eligibility ended. Under the rule used here, the assessment stays due when there was eligible collection time. A qualifying response collected before the event can count. If none was accepted, record the documented reason in the due-but-unreceived group. Use the study’s documented window and assignment rules. Visit and assessment windows · eCOA and clinical database reconciliation

  • Death before the assessment window. In the FDA and SISAQOL-IMI displays, assessments after death are outside the expected group. Keep those participants in the fixed randomized denominator for availability. FDA Table A6 also shows deaths separately in the clinical-benefit display. FDA specifications, §§4.1–4.2 and Table A6 · SISAQOL-IMI guidebook, Anal1_GEN

  • Off-treatment follow-up. Keep a participant due when the protocol calls for continued follow-up and collection is permitted. FDA’s clinical-benefit example includes protocol-designated visits after treatment discontinuation. For safety and tolerability, FDA recommends planning expectation in advance with the agency when post-discontinuation assessments become less frequent or stop. FDA specifications, §§4.1.1–4.1.2

  • Withdrawal from future PRO collection. Document what the participant withdrew from and when that change took effect. FDA’s withdrawal guidance keeps previously collected data in the database for FDA-regulated trials and describes the conditions for limited continued follow-up after withdrawal from the intervention. If a later score is uncollected and the estimand still needs it, it can remain analytically missing even when future PRO collection is no longer permitted. ICH E9(R1) distinguishes those cases from scores that cannot exist after death. FDA withdrawal guidance, §IV · ICH E9(R1), §A.4 · Withdrawal and retained trial data · Estimands and missing data

  • One-visit refusal, missed visit, illness, capture failure or unknown. Keep the assessment due when collection was scheduled and permitted. If event flags overlap, prespecify which documented reason takes precedence in the rollup and preserve the other flags with their dates and sources.

The Martin et al. simulation shows where missing expected assessments sit alongside assessments no longer expected after progression, withdrawal or death. Its follow-up schedule expected assessments after treatment discontinuation until progression. FDA’s clinical-benefit disposition example also has a separate category for other reasons an assessment was never expected, such as an unavailable translation in the patient’s language. Use a separate documented reason for that kind of design or administrative exclusion. Martin et al. (2026), Figure 3 · FDA specifications, §4.1.1

Reconcile two visits in a synthetic oncology trial

This synthetic oncology trial randomizes 40 participants to each arm. Each participant has one nominal opportunity per closed window for one instrument and one target score. All deaths and scoped withdrawals shown below predate the window they affect. Cycle 4 Due includes three participants off treatment in Arm A and five in Arm B whose protocol follow-up continued.

Cycle and armScheduledDueReceivedEvaluableEvaluable / DueEvaluable / Randomized
Cycle 2, Arm A4039353434/39 (87.2%)34/40 (85.0%)
Cycle 2, Arm B4038353434/38 (89.5%)34/40 (85.0%)
Cycle 4, Arm A4036323030/36 (83.3%)30/40 (75.0%)
Cycle 4, Arm B4028272626/28 (92.9%)26/40 (65.0%)
Cycle and armScheduled minus DueDue minus ReceivedReceived minus Evaluable
Cycle 2, Arm A1 death2 missed visits, 1 one-visit refusal, 1 unknown1 form without the target score
Cycle 2, Arm B1 death, 1 scoped withdrawal1 missed visit, 1 return outside the window only, 1 unknown1 form without the target score
Cycle 4, Arm A3 deaths, 1 scoped withdrawal1 missed visit, 1 illness, 1 capture failure, 1 unknown2 forms without the target score
Cycle 4, Arm B9 deaths, 3 scoped withdrawals1 unknown1 form without the target score

For each row, assign one reason to every assessment that drops out at each step and check that its reason counts sum to the difference. At Cycle 4 in Arm B, 12 of 40 scheduled opportunities were no longer due, one of 28 due yielded no accepted response, and one of 27 accepted responses yielded no target score. If the counts differ, check for duplicate occurrences, unmatched records and unclassified reasons. Also match the participant-level flags to the underlying records. An omitted assessment can cancel out a duplicate in a totals check.

PRO completion and score availability in the synthetic trial
visitArmEvaluable / Due (%)Evaluable / Randomized (%)
Cycle 2, Arm A87.285
Cycle 2, Arm B89.585
Cycle 4, Arm A83.375
Cycle 4, Arm B92.965

Percentages for closed windows with 40 participants randomized per arm. The preceding tables show the fractions and reasons for each difference.

Both arms started at 34 evaluable scores at Cycle 2. By Cycle 4, Arm B had eight fewer scores and its due group had shrunk by ten. Its operational completion rate rose from 89.5% to 92.9% while fixed-arm availability fell from 85.0% to 65.0%. The two rates describe score availability. Comparing the two rates does not estimate a treatment effect or establish why patients discontinued or withdrew.

Show the counts beside each percentage. If no assessments are due, display the operational rate as undefined and retain the disposition counts. A known visit, capture or scoring problem can be routed to the team that can resolve it. A shrinking due roster calls for checking the reasons and assessing how much of the randomized arm still provides a score. Reviewing PRO questionnaire burden

Carry the same definitions from collection to reporting

Agree on the metric definitions across the protocol, electronic clinical outcome assessment (eCOA) transfer specification, data management plan and SAP before collection begins. For every output, name the visit and reporting cutoff, identify the population or visit-specific group, and specify which response or score counts in the numerator. Validate the reporting flags even when an operational display uses the same rate name.

FrameworkRate and denominatorWhat counts in the numerator
FDA clinical benefit (§§4.1.1 and 4.2.1, Table A6)Availability over the randomized arm. Visit expectation includes protocol-designated off-treatment follow-up.Instrument completion follows its scoring manual. FDA also recommends displays for relevant item and summary scores.
FDA safety and tolerability (§§4.1.2 and 4.2.2, Table A7)Completion over the expected group at the visit. The separate disposition display uses the fixed safety population.Instrument-level completion follows the scoring manual. FDA recommends both objective-specific displays when both objectives apply.
SISAQOL-IMI (Anal1_GEN for randomized trials)Completion over those expected under the protocol and relevant intercurrent-event strategy. Availability over everyone randomized.Participants who completed the assessment at the time point in both rates.
LEAP-001 supplemental SAP (§3.6.3.1)CR-T uses treated participants in the PRO population. CR-E uses eligible participants expected to complete the assessment.Both rate formulas count a treated participant who answered at least one item. Instrument completeness separately requires a valid score.
Operational reconciliation in this exampleCompletion over operationally due assessments. Fixed-arm availability over everyone randomized.Evaluable target scores for both rates. Track accepted response-bearing records as a separate count.

Carry the date, source and reason behind each flag forward from collection to reporting. In FDA’s clinical-benefit dataset example, a placeholder can represent a planned time point after death. A placeholder preserves the planned row but supplies no observed PRO value. Count responses and scores from their own flags so a placeholder cannot increment either numerator. FDA technical specifications, §3.2.2.2

Trial artifact or gatePrimary ownerConcrete specification required
Protocol & Schedule of AssessmentsClinical operations & medical leadFix nominal visit schedule, window bounds, post-discontinuation follow-up rules, early-withdrawal collection (where permitted), and prospective missing-data mitigation.
eCOA Transfer Spec & Data Management PlanData managementSpecify effective dates for disposition and consent scope, completion and transfer times where available, visit assignment and cutoff rules, and reason provenance.
Scoring & Instrument SpecificationClinical outcome assessment leadLock instrument version, target item/subscale/total score definitions, missing-item scoring rules, and documented rationale for any scoring-manual departure.
Statistical analysis plan and analysis dataset metadataBiostatisticsSpecify the estimand, event strategies and objective-specific reporting denominators. Reconcile the PRO Expected Flag (PROEXPFL) to the intended reporting definition where applicable.
Monitoring and aggregate reviewClinical operations and authorized reviewersUse pooled or suitably masked outputs as allowed by the review plan. Limit treatment-arm access to reviewers authorized under the trial’s blinding and oversight procedures.

A score at a closed window establishes visit-level availability. Eligibility for analysis still depends on the prespecified model and estimand, including any baseline data needed for that analysis. Use operational monitoring to address capture, training and reconciliation problems. If a definition needs to change, document the rationale and apply the study’s change controls, preserving the definition used for each prior data cut.

Sources