Data Quality & Technology

How to Preserve Trial Scan Intervals When De-identifying DICOM Images

Choose a DICOM date-handling option and verify that exported trial scans preserve baseline-to-follow-up, midnight-crossing, and lab-linked intervals.

· · 9 min read

Two paired stacks of imaging films on a parchment board with a drafting divider spanning the gap, representing preserved longitudinal intervals.

If a vendor blanks the dates on follow-up scans, hold those scans from any endpoint calculation that needs elapsed time. First check whether the imaging charter allows a verified relative-day field or a separately governed timing feed that can be linked to the same studies. If neither exists, the header alone cannot establish the baseline-to-follow-up interval. Ask the vendor to reprocess the images through the approved workflow and show that the exported timestamps reproduce the intervals the endpoint uses.

For a trial that needs dates in the image set, the DICOM Modified Dates option gives teams a way to preserve those intervals while reducing the chance of matching against outside records. The acceptance test is to recompute the required intervals from what the readers and analysts actually receive. The option flag tells you how the vendor says the data were handled. The recomputation shows what survived. (DICOM PS3.15 2026d, E.3.6)

Specify the interval before choosing the DICOM option

Decide whether the endpoint needs visit order, calendar days between acquisitions, elapsed time between acquisitions, or the time from a separate event such as enrollment or specimen collection. A visit label can preserve order after the dates disappear. It cannot establish how many days actually passed or whether the scan fell inside the analysis window. Route missing or inconsistent timing through the assessment-window and deviation rules rather than substituting the scheduled day for the observed day.

DICOM PS3.15 2026d defines two mutually exclusive longitudinal options that can be applied with the Basic Application Level Confidentiality Profile. Longitudinal Temporal Information Modified (0028,0303) is UNMODIFIED with the Full Dates option and MODIFIED with the Modified Dates option. The table shows how selected fields change under each option. Combined action codes account for requirements of the DICOM object being processed. (E.3.6, Annex E, Table E.1-1)

DICOM attributeBasic ProfileFull DatesModified Dates
Study Date / Time (0008,0020) / (0008,0030)ZKC
Series Date / Time (0008,0021) / (0008,0031)X/DKC
Acquisition Date / Time (0008,0022) / (0008,0032)X/ZKC
Acquisition DateTime (0008,002A)X/Z/DKC
Content Date / Time (0008,0023) / (0008,0033)Z/DKC
Frame Acquisition DateTime (0018,9074)DKC
Timezone Offset From UTC (0008,0201)XKC

K keeps the value and C cleans it with a replacement that preserves relevant meaning and is known to contain no identifying information. X removes the attribute. Z allows an empty value or a nonempty replacement. D requires a nonempty replacement. A nonempty replacement must fit the attribute’s value representation and may be a dummy value. A populated timestamp after Basic Profile processing can therefore be a placeholder. Check the declared option and trace the actual field the reader or analysis export uses. (Annex E action codes)

Test date and time as one timestamp

Under the Modified Dates option, the transformation must make dates harder to match for re-identification and preserve timing at the precision the application needs. That covers both spacing between studies and finer relationships, such as the interval between injection and image acquisition used in PET standardized uptake value calculations, or the timing of measurements in dynamic contrast-enhanced imaging. DICOM calls for the Conformance Statement to describe how dates were modified. Its implementation notes call attention to studies that span midnight. (E.3.6)

Inventory the separate Date (DA) and Time (TM) fields, combined DateTime (DT) fields, and frame-level values that feed the endpoint. Agree on which acquisition event counts and how local time or UTC offsets are interpreted before and after export. A frame acquired after midnight needs the date of that frame. Reusing the study start date with the frame’s clock time can put it before the first frame. If the export loses the offset needed to compare timestamps across sites, establish an approved common time basis before using those timestamps to calculate elapsed time.

Match the treatment of time to the endpoint. DICOM describes aggregation such as moving dates to the first day of their month. That can support a month-level analysis when the resulting data still meet its requirements. It can collapse two different scan dates into one or change a day-level interval. If day-level windows or sub-day measurements drive the endpoint, test those quantities directly at the precision the analysis uses. (E.3.6 implementation notes)

Give imaging and trial data the same time anchor

DICOM PS3.3 2026d defines Longitudinal Temporal Offset from Event (0012,0052) in days, which may be fractional. In the Clinical Trial Study Module the offset is optional. When present, Longitudinal Temporal Event Type (0012,0053) must identify the anchor. ENROLLMENT and BASELINE are defined terms. Name the event and the timing convention in the charter so that an offset from enrollment and an offset from the baseline scan are interpreted correctly. (DICOM Clinical Trial Study Module)

An event-relative day answers how far the study falls from the specified anchor. The transformation used to move original dates onto a synthetic timeline is a separate, restricted record. For repeated transfers, have the authorized custodian keep the transformation consistent across occasions and across any imaging, electronic data capture (EDC), and laboratory exports that need to share a timeline. Join on the approved trial subject and time-point or specimen identifiers, then check the expected timing. Keep any reversible mapping in the authorized environment and out of reader packages, reports, and public materials.

The Cancer Imaging Archive’s historical curation documentation describes a subject-consistent random date offset that preserves a 120-day follow-up gap and uses the same offset for retained private date and date-time tags. It also lists some clock-time fields that were kept. The VAREPOP-APOLLO collection documents base-date normalization followed by a shift and reports MODIFIED in (0028,0303). These are examples of archive processing. A trial with sub-day endpoint requirements needs evidence from its own exported data. (TCIA curation documentation, VAREPOP-APOLLO, version 3)

A synthetic acceptance test for two imaging studies

Use one invented subject with a screening study that serves as the baseline and a follow-up study. Include a frame acquired after midnight in the first study and a follow-up lab collection from the EDC export. Apply one consistent shift to the four synthetic timestamps using a common fixed time basis. Run the fixture through the same export and import steps used for the central read and the analysis dataset.

Synthetic eventBefore transformationAfter transformation
Screening acquisition begins2026-03-09 23:412026-04-22 23:51
Screening frame after midnight2026-03-10 00:062026-04-23 00:16
Follow-up acquisition begins2026-06-01 00:152026-07-15 00:25
Follow-up lab specimen collected2026-06-01 00:452026-07-15 00:55
  1. Recalculate the scan interval. The start dates are 84 calendar days apart in each column. The elapsed time from the first acquisition start to the second is 83 days and 34 minutes in each column. Record which calculation the endpoint or visit-window rule uses.

  2. Reconstruct the midnight pair. The post-midnight frame is 25 minutes after the first acquisition begins in each column. Check the date and time together and verify that the frame stays with the same study after import.

  3. Link the lab collection to the follow-up study. The joined collection timestamp is 30 minutes after acquisition begins before and after transformation. Use the trial identifiers to confirm the join, then test the time difference.

  4. Verify the markers on the delivered objects. This fixture expects (0028,0303) = MODIFIED, Patient Identity Removed (0012,0062) = YES, and the selected profile and option in the method codes agreed for intake. If the fixture carries a BASELINE event offset, verify that it uses the screening acquisition as its anchor.

Include a failing case. Give the post-midnight frame the preceding date and confirm the import check rejects the resulting reversed sequence. Then move only the transformed lab date forward a day and confirm the cross-system check detects 24 hours and 30 minutes in place of 30 minutes. Repeat the tests with a follow-up exported separately from its baseline to catch inconsistent subject transformations between batches. Record the configuration, expected and observed results, and disposition. These synthetic checks exercise timing behavior under the tested configuration.

Decide which privacy route permits the delivered precision

For a U.S. release relying on HIPAA de-identification, Safe Harbor generally requires removal of all date elements finer than year for dates directly related to an individual. It also specifies other identifier removals, special treatment of ages over 89, and a condition on actual knowledge of identifiability. Shifted full dates still carry month and day elements, and the regulation’s text provides no exception for shifted values, so do not assume a shifted-date release qualifies under Safe Harbor. When retaining sub-year dates in data treated as de-identified, the Expert Determination route calls for an appropriately qualified person to document the methods and results supporting a very small re-identification risk for the anticipated recipient. (45 CFR 164.514(b))

For qualifying U.S. research disclosures, a limited data set can retain dates under a data use agreement if it meets the applicable identifier exclusions and other conditions. It remains protected health information. Where a covered entity assigns a re-identification code under paragraph (c), the code must be independent of the individual’s information and incapable of translation into their identity. The covered entity must keep the re-identification mechanism undisclosed. Review the planned recipient, the consent and disclosure basis, and the timing precision together. When the endpoint needs only visit order and the approved visit identifiers supply it, dates can be removed. (45 CFR 164.514(c) and (e))

Make interval verification part of imaging intake

FDA’s April 2018 final guidance discusses acquisition, display, archiving, and interpretation when imaging assesses a primary endpoint or a component of it. Write your trial’s timing requirement, evidence, and escalation path into the imaging charter so that the vendor, central read team, and statisticians work from the same field and definition. RSNA’s Clinical Trial Processor is an example of a tool for moving and anonymizing DICOM objects. Configuration and export testing are what establish whether its output meets a given trial’s endpoint needs. (FDA imaging endpoint process standards, RSNA Clinical Trial Processor)

  • Imaging vendor. Provide the declared DICOM profile and longitudinal option, the Conformance Statement’s description of the date modification, and header samples showing (0028,0303) and (0012,0062). Include CID 7050 codes in (0012,0064) if the trial specifies them as intake evidence. Annex E permits method text in (0012,0063), codes in (0012,0064), or both.

  • Central read team. Confirm participant and visit linkage, the accepted timestamp field and its precision, the event-offset pair when specified, and the midnight result in the actual reader import. Keep the burned-in identifier check in the intake workflow. Timing tests examine metadata and derived values.

  • Data management and statistics. Compare source and exported scan gaps and external-data joins at the precision specified in the charter and statistical analysis plan. Hold the affected records from time-dependent use if the evidence is missing or a check fails. Resolve the discrepancy with the authorized source team, rerun the checks, and document the release decision.

Record privacy and endpoint acceptance separately. DICOM describes its confidentiality profiles as one part of a broader de-identification process. A release decision needs both a permitted privacy route and evidence that the delivered records still support the intended measurement. (DICOM PS3.15, Annex E)

Sources